ultrafast transient absorption
Ni-CAT-1 thin film on quartz · Thin Film
100 fs pump-probe; pump 400 nm for Figure 5 and 350 nm control in SI; probe broad-band white light; time delay up to 3 ns.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| 350 nm excitation density | 29 uJ cm^-2 | — | — | Caption Exact Reported | S35 · Transient absorption plots · Figure S5.6 |
| control pump wavelength | 350 nm | — | — | Caption Exact Reported | S35 · Transient absorption plots · Figure S5.6 |
| excitation density | 173 uJ cm^-2 per pulse | — | — | Caption Exact Reported | p005 · Figure caption · Figure 5 |
| TA fitted lifetime at 116 uJ cm^-2 | tau = 2.4 ns | — | +/- 0.5 ns | Visual Estimate Approximate | p005 · TA kinetics · Figure 5b |
| TA fitted lifetime at 173 uJ cm^-2 | tau = 2.1 ns | — | +/- 0.3 ns | Visual Estimate Approximate | p005 · TA kinetics · Figure 5b |
| long-time fitted lifetime | longer than 2 ns | — | — | Text Approximate | p006 · TA dynamics · Figure 5b |
| pump wavelength | 400 nm | — | — | Caption Exact Reported | p005 · Figure caption · Figure 5 |
| signal remaining after 3 ns | nearly 15% of initial signal | — | — | Text Approximate | p006 · TA dynamics · Figure 5b |