Diffraction Structure — A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity

Measurement evidence

Diffraction Structure

A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity · Scheurle P.I., Biewald A., Mahringer A. et al. · Small Structures · 2022 · 2100195

4 measurement groups · 25 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

GIWAXS/GISAXS and XRD

PDI-MOF-74(Zn) VAC film on glass · Thin Film

PDI-MOF-74(Zn) film grown on glass by VAC; diffraction confirms crystalline film with random crystallite distribution

Geometry
thin-film X-ray scattering/diffraction
Context
pristine
Measurement source
3, SI 35 · Results and Discussion · Figures S28-S29
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
film crystallinitycrystalline film with random crystallite distribution——Text
Qualitative
3 · Results and Discussion · Figures S28-S29

powder X-ray diffraction; Pawley refinement

PDI-MOF-74(Mg) powder · Powder

Bruker D8, Cu Kalpha; simulated MOF-74 model refined to experimental PXRD; best refinements in triclinic P1

Geometry
powder PXRD
Context
pristine
Measurement source
2-3, SI 10-22 · Results and Discussion · Figure 2; Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
triclinic lattice parameter a72.6294 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter b74.5613 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter c5.5891 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
pi-pi stacking distance between adjacent PDI cores3.4 A——Text
Rounded Reported
3 · Results and Discussion · Figure 2
modelled hexagonal channel aperture4.0-4.5 nm——Text
Range
3 · Results and Discussion · Figure 1; Figure S1
pronounced PXRD reflections2.45, 3.97, 4.76, 6.31, 8.18, 10.66, 11.97 degrees 2theta——Text
Exact Reported
2 · Results and Discussion · Figure 2
Pawley Rp triclinic refinement2.29%——Text
Exact Reported
10, 20-21 · Unit cell parameters
Pawley Rwp triclinic refinement3.23%——Text
Exact Reported
10, 20-21 · Unit cell parameters

powder X-ray diffraction; Pawley refinement

PDI-MOF-74(Ni) powder · Powder

Bruker D8, Cu Kalpha; simulated MOF-74 model refined to experimental PXRD; best refinements in triclinic P1

Geometry
powder PXRD
Context
pristine
Measurement source
2-3, SI 10-22 · Results and Discussion · Figure 2; Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
triclinic lattice parameter a72.2829 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter b75.6727 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter c5.5574 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
pi-pi stacking distance between adjacent PDI cores3.3 A——Text
Rounded Reported
3 · Results and Discussion · Figure 2
modelled hexagonal channel aperture4.0-4.5 nm——Text
Range
3 · Results and Discussion · Figure 1; Figure S1
pronounced PXRD reflections2.45, 3.97, 6.31, 8.04/8.48, 10.35/10.88, 11.70 degrees 2theta——Text
Exact Reported
2 · Results and Discussion · Figure 2
Pawley Rp triclinic refinement2.75%——Text
Exact Reported
10, 20-21 · Unit cell parameters
Pawley Rwp triclinic refinement3.96%——Text
Exact Reported
10, 20-21 · Unit cell parameters

powder X-ray diffraction; Pawley refinement

PDI-MOF-74(Zn) powder · Powder

Bruker D8, Cu Kalpha; simulated MOF-74 model refined to experimental PXRD; best refinements in triclinic P1

Geometry
powder PXRD
Context
pristine
Measurement source
2-3, SI 10-22 · Results and Discussion · Figure 2; Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
triclinic lattice parameter a72.6294 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter b74.5613 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
triclinic lattice parameter c5.5891 A——Text
Exact Reported
10, 20-21 · Unit cell parameters
pi-pi stacking distance between adjacent PDI cores3.4 A——Text
Rounded Reported
3 · Results and Discussion · Figure 2
modelled hexagonal channel aperture4.0-4.5 nm——Text
Range
3 · Results and Discussion · Figure 1; Figure S1
pronounced PXRD reflections2.45, 3.97, 8.10, 10.52, 12.01 degrees 2theta——Text
Exact Reported
2 · Results and Discussion · Figure 2
Pawley Rp triclinic refinement1.56%——Text
Exact Reported
10, 20-21 · Unit cell parameters
Pawley Rwp triclinic refinement2.38%——Text
Exact Reported
10, 20-21 · Unit cell parameters