Spectroscopy — A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity

Measurement evidence

Spectroscopy

A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity · Scheurle P.I., Biewald A., Mahringer A. et al. · Small Structures · 2022 · 2100195

3 measurement groups · 21 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

UV-vis diffuse reflectance, PL, TCSPC

PDI-MOF-74(Mg) powder · Powder

UV-vis diffuse reflectance with BaSO4/Kubelka-Munk; PL excitation 405 nm; TCSPC with 476 nm excitation recorded at emission maxima

Geometry
powder spectroscopy
Context
pristine
Measurement source
4-5, SI 31-33 · Results and Discussion · Figure 5; Figure S23
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
UV-vis absorption maximumabout 498 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption maximumabout 545 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption onsetaround 622-627 nmText
Range
4 · Results and Discussion · Figure 5A
direct optical band gap2.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
PL emission maximumMarked as a best value within this paper660 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C
medium PL lifetimeMarked as a best value within this paper430 psText
Rounded Reported
5 · Results and Discussion · Figure 5D-F
Stokes shift115 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C

UV-vis diffuse reflectance, PL, TCSPC

PDI-MOF-74(Ni) powder · Powder

UV-vis diffuse reflectance with BaSO4/Kubelka-Munk; PL excitation 405 nm; TCSPC with 476 nm excitation recorded at emission maxima

Geometry
powder spectroscopy
Context
pristine
Measurement source
4-5, SI 31-33 · Results and Discussion · Figure 5; Figure S23
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
UV-vis absorption maximumabout 498 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption maximumabout 545 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption onsetaround 622-627 nmText
Range
4 · Results and Discussion · Figure 5A
direct optical band gap2.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
PL emission maximum640 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C
medium PL lifetime60 psText
Rounded Reported
5 · Results and Discussion · Figure 5D-F
Stokes shift95 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C

UV-vis diffuse reflectance, PL, TCSPC

PDI-MOF-74(Zn) powder · Powder

UV-vis diffuse reflectance with BaSO4/Kubelka-Munk; PL excitation 405 nm; TCSPC with 476 nm excitation recorded at emission maxima

Geometry
powder spectroscopy
Context
pristine
Measurement source
4-5, SI 31-33 · Results and Discussion · Figure 5; Figure S23
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
UV-vis absorption maximumabout 498 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption maximumabout 545 nmText
Approximate
4 · Results and Discussion · Figure 5A
UV-vis absorption onsetaround 622-627 nmText
Range
4 · Results and Discussion · Figure 5A
direct optical band gap2.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
PL emission maximum660 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C
medium PL lifetime160 psText
Rounded Reported
5 · Results and Discussion · Figure 5D-F
Stokes shift115 nmText
Rounded Reported
4-5 · Results and Discussion · Figure 5C