Electrochemistry Application — A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity

Measurement evidence

Electrochemistry Application

A Novel Electrically Conductive Perylene Diimide-Based MOF-74 Series Featuring Luminescence and Redox Activity · Scheurle P.I., Biewald A., Mahringer A. et al. · Small Structures · 2022 · 2100195

3 measurement groups · 15 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

cyclic voltammetry

PDI-MOF-74(Mg) CV mesh electrode · Electrode

Three-electrode setup; Pt-wire counter electrode; silver wire pseudo-reference; dry DMF; 0.1 M TBAPF6; scan rate 0.1 V/s; argon; ferrocene added after CV for reference

Atmosphere
argon
Geometry
MOF pressed into stainless steel mesh
Context
composite
Measurement source
5-6, SI 4 and 33 · Results and Discussion · Figure 6; Figure S26; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV cycling stabilitystable during several cyclesText
Qualitative
6 · Results and Discussion · Figure S26
first reduction onset potential-0.2 V vs Ag/Ag+SI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
second reduction onset potential-0.5 V vs Ag/Ag+Text
Rounded Reported
6 · Results and Discussion · Figure 6; Figure S26
HOMO / valence-band edge against vacuum-6.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
LUMO / conduction-band edge against vacuum-4.0 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2

cyclic voltammetry

PDI-MOF-74(Ni) CV mesh electrode · Electrode

Three-electrode setup; Pt-wire counter electrode; silver wire pseudo-reference; dry DMF; 0.1 M TBAPF6; scan rate 0.1 V/s; argon; ferrocene added after CV for reference

Atmosphere
argon
Geometry
MOF pressed into stainless steel mesh
Context
composite
Measurement source
5-6, SI 4 and 33 · Results and Discussion · Figure 6; Figure S26; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV cycling stabilitystable during several cyclesText
Qualitative
6 · Results and Discussion · Figure S26
first reduction onset potential-0.2 V vs Ag/Ag+SI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
second reduction onset potential-0.5 V vs Ag/Ag+Text
Rounded Reported
6 · Results and Discussion · Figure 6; Figure S26
HOMO / valence-band edge against vacuum-6.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
LUMO / conduction-band edge against vacuum-4.0 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2

cyclic voltammetry

PDI-MOF-74(Zn) CV mesh electrode · Electrode

Three-electrode setup; Pt-wire counter electrode; silver wire pseudo-reference; dry DMF; 0.1 M TBAPF6; scan rate 0.1 V/s; argon; ferrocene added after CV for reference

Atmosphere
argon
Geometry
MOF pressed into stainless steel mesh
Context
composite
Measurement source
5-6, SI 4 and 33 · Results and Discussion · Figure 6; Figure S26; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV cycling stabilitystable during several cyclesText
Qualitative
6 · Results and Discussion · Figure S26
first reduction onset potential-0.2 V vs Ag/Ag+SI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
second reduction onset potential-0.5 V vs Ag/Ag+Text
Rounded Reported
6 · Results and Discussion · Figure 6; Figure S26
HOMO / valence-band edge against vacuum-6.1 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2
LUMO / conduction-band edge against vacuum-4.0 eVSI Table
Exact Reported
33 · Cyclic voltammetry · Table S2