four-probe van der Pauw method using Keithley 2400 digital source meter
(001)-oriented Cu3(HHTP)2 thin film annealed with 3 uL pyridine · Thin Film
Room-temperature in-plane conductivity; Au electrodes at four corners, 5 mm x 5 mm film specimen, electrode distance about 3 mm; currents 1.00 x 10^-8 to 5.00 x 10^-7 A.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| annealed conductivity at 1.00 x 10^-7 A | 2.6 x 10^-2 S cm^-1 | — | — | SI Table Rounded Reported | p004 · Table S1 · Table S1 |
| annealed conductivity at 1.00 x 10^-8 AMarked as a best value within this paper | 2.6 x 10^-2 S cm^-1 | — | — | SI Table Rounded Reported | p004 · Table S1 · Table S1 |
| annealed conductivity at 5.00 x 10^-7 A | 2.6 x 10^-2 S cm^-1 | — | — | SI Table Rounded Reported | p004 · Table S1 · Table S1 |
| annealed conductivity at 5.00 x 10^-8 A | 2.6 x 10^-2 S cm^-1 | — | — | SI Table Rounded Reported | p004 · Table S1 · Table S1 |
| conductivity current-independence indicates ohmic contact | constancy of conductivity over the entire current range indicates ohmic contact | — | — | Caption Qualitative | p004 · Table caption · Table S1 |