Diffraction Structure — High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks

Measurement evidence

Diffraction Structure

High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks · Wang B., Luo Y., Gao L. et al. · Biosensors and Bioelectronics · 2021 · 112736

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

PXRD

Ni/Cu-MOFs (7:1)-FET · Electrode

PXRD patterns of Ni-MOFs, Cu-MOFs and Ni/Cu-MOFs (7:1) films compared.

Geometry
thin films on FET/device substrate
Context
pristine mixed-metal framework compared with monometallic controls
Measurement source
3 · 3.1 · Fig. 2a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PXRD peak positions2theta = 4.7, 9.5, 12.5, 16.5 and 27.1 degText
Rounded Reported
3 · 3.1 · Fig. 2a
PXRD plane assignments4.7, 9.5 and 27.1 deg assigned to (100), (200) and (001) planes, respectivelyText
Qualitative
3 · 3.1 · Fig. 2a