Electrical Transport — High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks

Measurement evidence

Electrical Transport

High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks · Wang B., Luo Y., Gao L. et al. · Biosensors and Bioelectronics · 2021 · 112736

3 measurement groups · 10 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

liquid-gated FET output and transfer curves

Ni/Cu-MOFs (7:1)-FET · Electrode

Measured with Keithley 4200-SCS and four-point probe station; PBS liquid gate with silver probe; output Vgs 0.1 to -0.1 V at Vds 0 to -0.2 V; transfer Vds = -0.10 V and Vgs -0.15 to 0.15 V.

Atmosphere
PBS liquid gate
Geometry
liquid-gated FET
Context
pristine mixed-metal FET compared with Ni-MOFs-FET and Cu-MOFs-FET
Measurement source
2-3,5 · 2.5; 3.2 · Fig. S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
relative FET current increaseMarked as a best value within this papercurrent value of Ni/Cu-MOFs (7:1)-FET increased by an order of magnitudeText
Approximate
5 · 3.2 · Fig. S9
Ids-Vds ohmic behaviourMarked as a best value within this paperNi/Cu-MOFs (7:1)-FET showed good ohmic characteristics and better linearity than Ni-MOFs-FET and Cu-MOFs-FETText
Qualitative
5 · 3.2 · Fig. S9

liquid-gated FET transfer analysis

GOD-GA-Ni/Cu-MOFs (7:1)-FET · Electrode

Maximum transconductance, carrier mobility, switching ratio and threshold voltage calculated for GOD-GA-Ni/Cu-MOFs (7:1)-FET.

Atmosphere
PBS liquid gate
Geometry
liquid-gated enzyme FET
Context
functionalised target device
Measurement source
5 · 3.2 · Fig. S10; Formula S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FET channel length used for mobility calculation50 umText
Exact Reported
S1; S3
FET channel width used for mobility calculation1000 umText
Exact Reported
S1; S3
maximum transconductanceMarked as a best value within this paper20.47 uSText
Exact Reported
5 · 3.2 · Fig. S10
electric double-layer capacitance used for mobility calculation25.52 uF cm^-2Text
Exact Reported
S3 · Formula S1
carrier mobilityMarked as a best value within this paper401.05 cm2 V^-1 s^-1Text
Exact Reported
5 · 3.2 · Formula S1
current switching ratioIon/Ioff = 4.89Text
Exact Reported
5 · 3.2
threshold voltage0.32 VText
Exact Reported
5 · 3.2

pH-dependent I-Vds conductance fitting

GOD-GA-Ni/Cu-MOFs (7:1)-FET · Electrode

GOD-GA-Ni/Cu-MOFs (7:1)-FET measured at pH 5.8, 6.4, 6.8, 7.4 and 8 using 5 uL PBS solution; Vgs = -0.1 V.

Atmosphere
PBS liquid gate
Geometry
liquid-gated enzyme FET
Context
functionalised target device
Measurement source
S11 · Supporting Information · Fig. S11
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
selected glucose detection pHpH 7.4Text
Exact Reported
5-6 · 3.3 · Fig. S11