Current-voltage measurement
BPA@Cu(BDC)-SURMOF-2 after electropolymerisation · Electrode
Keithley 2635B SourceMeter; pure nitrogen; sample equilibrated at least 2 h in nitrogen before measurement; room temperature.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| BPA@Cu(BDC)-SURMOF-2 conductivityMarked as a best value within this paper | 0.098 S m-1 | 0.098 S m-1 | — | Text Exact Reported | main p.5 · Results and Discussion · Figure 4 |
| Conductivity increase after in-pore EP | 8 orders of magnitude | — | — | Text Rounded Reported | main p.5 · Results and Discussion · Figure 4 |
| I-V stability after argon storage | I-V curve after 3 months virtually identical | — | — | Caption Qualitative | main p.5 · Figure 4 caption · Figure 4 |
| Approximate target current at +/-1 V in I-V plot | about 1 x 10-3 A at +/-1 V | — | visual estimate from log-axis plot | Figure Axis Approximate | main p.5 · Results and Discussion · Figure 4 |