Cyclic voltammetry
1-hexyne-loaded Cu(BDC) SURMOF-2 · Thin Film
Dry dichloromethane with 0.1 M TBAHFP/TBAF supporting electrolyte, argon atmosphere in main text; 20 mM 1-hexyne present or absent; working electrode Cu(BDC)/(Au@Si), counter Pt-wire, reference Ag/Ag+.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Substantial current density for 1-hexyne-loaded samples | 10 mA cm-2 | — | — | Text Rounded Reported | main p.4 · Results and Discussion · Figure S3 |
| No redox process from Cu paddlewheel | No evidence of Cu-node redox processes observed | — | — | Text Qualitative | main p.4 · Results and Discussion · Figure S3 |
| Oxidation peak assigned to 1-hexyne | +0.5 V vs Ag/Ag+ (irreversible) | — | — | Figure Axis Rounded Reported | SI p.S-5 · Figure S3 caption and embedded table · Figure S3 |
| Irreversible cathodic reduction peak | -1.25 V vs Ag/Ag+ | — | — | Text Exact Reported | main p.4 · Results and Discussion · Figure S3 |
| Irreversible cathodic reduction peak | -1.60 V vs Ag/Ag+ | — | — | Text Exact Reported | main p.4 · Results and Discussion · Figure S3 |