Hydrodynamic diameter and zeta potential monitoring
CM nanosheets · Nanosheet
CM dispersions in water, PBS (pH 7.4), and RPMI-1640 culture medium monitored over 14 days; zeta potential measured on day 0 and day 14.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CM hydrated diameter range over 14 days in physiological media | approximately 175-195 nm across water, PBS and 1640 medium over 14 days | — | visual range about 175-195 nm | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4a |
| CM zeta potential in RPMI-1640 medium at day 0 | about -14.0 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4d |
| CM zeta potential in RPMI-1640 medium at day 14 | about -14.2 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4d |
| CM zeta potential in PBS at day 0 | about -14.0 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4c |
| CM zeta potential in PBS at day 14 | about -14.5 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4c |
| CM zeta potential in water at day 0 | about -14.5 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4b |
| CM zeta potential in water at day 14 | about -14.8 mV | — | visual estimate from bar plot | Visual Estimate Approximate | S11 · Supplementary figures · Fig. S4b |