Electrical Transport — Chromone-Based Cd(II) Fluorescent Coordination Polymer Fabricated to Study Optoelectronic and Explosive Sensing Properties

Measurement evidence

Electrical Transport

Chromone-Based Cd(II) Fluorescent Coordination Polymer Fabricated to Study Optoelectronic and Explosive Sensing Properties · Mandal J., Dey A., Sarkar S. et al. · Inorganic Chemistry · 2024 · 4527-4544

7 measurement groups · 67 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Cheung's method analysis of I-V data

CSD1 thin-film Schottky device from CP1 · Thin Film

Ideality factor, barrier height and series resistance extracted from dV/dlnI vs I and H(I) vs I plots under dark and light.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP/Al Schottky devices
Context
pristine CP thin-film devices
Measurement source
S23-S65 · Electrical Characterization · Figures 7-8; Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CSD1 barrier height dark0.51 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD1 barrier height light0.42 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD1 ideality factor dark3.11SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD1 ideality factor light2.47SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD1 series resistance from dV/dlnI dark6005.27 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD1 series resistance from dV/dlnI light3577.35 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 barrier height dark0.46 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 barrier height light0.37 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 ideality factor dark2.67SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 ideality factor light2.04SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 series resistance from dV/dlnI dark5034.83 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD2 series resistance from dV/dlnI light2729.14 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 barrier height dark0.45 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 barrier height light0.37 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 ideality factor dark2.73SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 ideality factor light1.92SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 series resistance from dV/dlnI dark4441.65 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD3 series resistance from dV/dlnI light2309.28 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 barrier height darkMarked as a best value within this paper0.41 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 barrier height lightMarked as a best value within this paper0.32 eVSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 ideality factor darkMarked as a best value within this paper2.32SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 ideality factor lightMarked as a best value within this paper1.43SI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 series resistance from dV/dlnI darkMarked as a best value within this paper3984.37 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4
CSD4 series resistance from dV/dlnI lightMarked as a best value within this paper1494.60 ohmSI Table
Exact Reported
S65 · Table S4 · Table S4

Two-probe current-voltage (I-V) control measurements

Bare ITO control · Electrode

Bare ITO, LSD1 and LSD2 measured under dark and light in same +/-2 V range.

Atmosphere
ambient
Geometry
Bare ITO or ligand/ITO/Al controls
Context
control samples
Measurement source
S22-S24 · Electrical Characterization · Figures S34-S35; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Bare ITO conductivity dark5.22 x 10-3 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
Bare ITO conductivity light5.38 x 10-3 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
LSD1 conductivity dark2.39 x 10-7 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
LSD1 conductivity light2.91 x 10-7 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
LSD2 conductivity dark2.37 x 10-7 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
LSD2 conductivity light2.92 x 10-7 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3

Two-probe current-voltage (I-V) measurement with Keithley source-meter

CSD1 thin-film Schottky device from CP1 · Thin Film

Bias +/-2 V, dark and illumination; light intensity approximately 100 mW cm-2; room temperature / 300 K.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP1/Al metal-semiconductor junction; Al top electrode
Context
pristine CP thin-film device
Measurement source
4532 · Electrical Characterization · Figure 6; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CSD1 conductivity dark1.37 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD1 conductivity light5.06 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD1 on/off ratio dark21.14SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD1 on/off ratio light38.42SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD1 photosensitivity2.75SI Table
Exact Reported
S64 · Table S3 · Table S3

Two-probe current-voltage (I-V) measurement with Keithley source-meter

CSD2 thin-film Schottky device from CP2 · Thin Film

Bias +/-2 V, dark and illumination; light intensity approximately 100 mW cm-2; room temperature / 300 K.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP2/Al metal-semiconductor junction; Al top electrode
Context
pristine CP thin-film device
Measurement source
4532 · Electrical Characterization · Figure 6; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CSD2 conductivity dark1.85 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD2 conductivity light8.78 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD2 on/off ratio dark23.65SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD2 on/off ratio light42.97SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD2 photosensitivity5.04SI Table
Exact Reported
S64 · Table S3 · Table S3

Two-probe current-voltage (I-V) measurement with Keithley source-meter

CSD3 thin-film Schottky device from CP3 · Thin Film

Bias +/-2 V, dark and illumination; light intensity approximately 100 mW cm-2; room temperature / 300 K.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP3/Al metal-semiconductor junction; Al top electrode
Context
pristine CP thin-film device
Measurement source
4532 · Electrical Characterization · Figure 6; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CSD3 conductivity dark1.61 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD3 conductivity light7.26 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD3 on/off ratio dark34.54SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD3 on/off ratio light67.59SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD3 photosensitivity3.01SI Table
Exact Reported
S64 · Table S3 · Table S3

Two-probe current-voltage (I-V) measurement with Keithley source-meter

CSD4 thin-film Schottky device from CP4 · Thin Film

Bias +/-2 V, dark and illumination; light intensity approximately 100 mW cm-2; room temperature / 300 K.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP4/Al metal-semiconductor junction; Al top electrode
Context
pristine CP thin-film device
Measurement source
4532 · Electrical Characterization · Figure 6; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CSD4 conductivity darkMarked as a best value within this paper2.01 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD4 conductivity lightMarked as a best value within this paper10.21 x 10-5 S m-1SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD4 on/off ratio darkMarked as a best value within this paper37.93SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD4 on/off ratio lightMarked as a best value within this paper81.79SI Table
Exact Reported
S64 · Table S3 · Table S3
CSD4 photosensitivityMarked as a best value within this paper8.44SI Table
Exact Reported
S64 · Table S3 · Table S3

SCLC/Mott-Gurney analysis; capacitance-derived dielectric constant

CSD1 thin-film Schottky device from CP1 · Thin Film

Effective mobility, transit time, mobility-time product and diffusion coefficient extracted from SCLC region in dark and light.

Temperature
300
Atmosphere
ambient
Geometry
ITO/CP/Al Schottky devices
Context
pristine CP thin-film devices
Measurement source
S24-S65 · Electrical Characterization · Figure S36; Table S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CP1 relative dielectric constant3.78 x 10-1SI Table
Exact Reported
S24-S65 · Electrical Characterization; Table S5 · Figure S36; Table S5
CP2 relative dielectric constantMarked as a best value within this paper5.48 x 10-1SI Table
Exact Reported
S24-S65 · Electrical Characterization; Table S5 · Figure S36; Table S5
CP3 relative dielectric constant4.14 x 10-1SI Table
Exact Reported
S24-S65 · Electrical Characterization; Table S5 · Figure S36; Table S5
CP4 relative dielectric constant6.89 x 10-2SI Table
Exact Reported
S24-S65 · Electrical Characterization; Table S5 · Figure S36; Table S5
CSD1 diffusion coefficient dark2.71 x 10-7SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD1 effective mobility dark1.05 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD1 effective mobility light6.94 x 10-4 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD1 transit time dark14.24 x 10-9 secSI Table
Exact Reported
S65 · Table S5 · Table S5
CSD1 transit time light4.27 x 10-9 secSI Table
Exact Reported
S65 · Table S5 · Table S5
CSD2 effective mobility dark2.47 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD2 effective mobility light15.71 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD3 effective mobility darkMarked as a best value within this paper7.68 x 10-4 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD3 effective mobility light23.54 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD4 diffusion coefficient lightMarked as a best value within this paper55.76 x 10-6SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD4 effective mobility dark44.54 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD4 effective mobility lightMarked as a best value within this paper216.14 x 10-5 m2 V-1 s-1SI Table
Exact Reported
S65 · Table S5 · Table S5
CSD4 transit time lightMarked as a best value within this paper3.37 x 10-10 secSI Table
Exact Reported
S65 · Table S5 · Table S5