Two-probe photodetector electrical measurement with Keithley 4200 semiconductor analysis system
In-TCPP SURMOF-based two-terminal photodetector · Electrode
Responsivity and detectivity under 420 nm irradiation at 1 mW cm-2 and 10 V bias; wavelength response 365-600 nm.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| photodetector bias voltage | 10 V | — | — | Text Exact Reported | 5 · Results and Discussion · Figure 3 |
| detectivity at 420 nmMarked as a best value within this paper | 7.28 x 10^14 Jones | — | — | Text Exact Reported | 3,5 · Results and Discussion · Figure 3; Table S2 |
| effective illuminated area | 0.01 cm2 | — | — | Text Exact Reported | 6 · Fabrication of In-TCPP based photodetector |
| fall timeMarked as a best value within this paper | 0.04 s | — | — | Text Exact Reported | 5 · Results and Discussion · Figure 3f |
| irradiation power density for best metrics | 1 mW cm-2 | — | — | Text Exact Reported | 5 · Results and Discussion · Figure 3d |
| best on/off ratioMarked as a best value within this paper | 6.8 x 10^6 | — | — | Text Exact Reported | 4 · Results and Discussion · Figure 3c |
| time-resolved photocurrent plateau at 420 nm | approximately 155 uA | — | — | Visual Estimate Approximate | 5 · Results and Discussion · Figure 3d |
| responsivity at 365 nm | approximately 6.5 A W-1 | — | — | Visual Estimate Approximate | 5 · Results and Discussion · Figure 3b |
| responsivity at 550 nm | approximately 3.3 A W-1 | — | — | Visual Estimate Approximate | 5 · Results and Discussion · Figure 3b |
| responsivity at 420 nmMarked as a best value within this paper | 30.8 A W-1 | — | — | Text Exact Reported | 5 · Results and Discussion · Figure 3; Table S2 |
| rise timeMarked as a best value within this paper | 0.07 s | — | — | Text Exact Reported | 5 · Results and Discussion · Figure 3f |