Porosity — An Enzyme-Encapsulated Metal-Organic Frameworks Nanomesh Biosensor for Salivary Glucose Detection

Measurement evidence

Porosity

An Enzyme-Encapsulated Metal-Organic Frameworks Nanomesh Biosensor for Salivary Glucose Detection · Wang M., Wang H., Cheng J. · Advanced Materials Technologies · 2024 · 2301678

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

BET pore distribution

CNT/GOx@ZIF-8 nanomesh · Powder

Pore distribution compared for ZIF-8, CNT/ZIF-8 and CNT/GOx@ZIF-8.

Context
Composite target with pristine/composite controls.
Measurement source
p003 · 2.2. Characterization of CNT/GOx@ZIF-8 · Figure 2f
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Glucose molecular size used for pore-access comparisonapproximately 0.7 nmText
Approximate
p003 · 2.2. Characterization of CNT/GOx@ZIF-8 · Figure 2f
CNT/GOx@ZIF-8 mesopore size150 nmText
Rounded Reported
p003 · 2.2. Characterization of CNT/GOx@ZIF-8 · Figure 2f
CNT/GOx@ZIF-8 micropore size1.37 nmText
Rounded Reported
p003 · 2.2. Characterization of CNT/GOx@ZIF-8 · Figure 2f