GOx Michaelis-Menten and Lineweaver-Burk kinetic-control analysis by UV-vis at 652 nm
GOx electrode / GOx in solution · Electrode
GOx control measured with TMB chromogenic curves at glucose concentrations of 0.5, 1, 4 and 8 mM; kinetic fits shown in Figure S2c,d.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| GOx solution comparison KM | 2.60 mM | — | — | Text Exact Reported | p004 · 2.3. Catalytic Properties of CNT/GOx@ZIF-8 · Figure 3d,e; SI Figure S2c,d |
| GOx Lineweaver-Burk fit equation | y = 2.4352*10^3 x + 0.9349*10^3 | 934.9 intercept in plotted Lineweaver-Burk units | — | Figure Axis Rounded Reported | SI p.3 · Figure S2 · Figure S2d |
| GOx solution comparison Vmax | 1.070 uM s-1 | — | — | Text Exact Reported | p004 · 2.3. Catalytic Properties of CNT/GOx@ZIF-8 · Figure 3d,e; SI Figure S2c,d |