Sensing Application — Mutually Noninterfering Flexible Pressure-Temperature Dual-Modal Sensors Based on Conductive Metal-Organic Framework for Electronic Skin

Measurement evidence

Sensing Application

Mutually Noninterfering Flexible Pressure-Temperature Dual-Modal Sensors Based on Conductive Metal-Organic Framework for Electronic Skin · Li Y., Wang R., Wang G.-E. et al. · ACS Nano · 2022 · 473-484

6 measurement groups · 38 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

3 x 3 array pressure-temperature mapping

3 x 3 MOF-MSMC-5h sensor array · Electrode

spatial dual-modal detection of bottles/water pouring

Context
array demonstration
Measurement source
480-481 · Dual-Modal Applications · Figure 5; Figure S15
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
3 x 3 array dynamic mass and temperature monitoringmass increase and temperature decrease observed clearlyQualitative
Qualitative
481 · Figure 5e-k
3 x 3 array static pressure-temperature separationpressure map matches two bottles; thermal voltage only hot-water positionQualitative
Qualitative
481 · Figure 5a-d

rat implantation histological scoring

MOF-MSMC-5h sensor sealed by PDMS implant · Electrode

biocompatibility of PDMS-sealed MOF-MSMC implant versus control

Context
implant demonstration
Measurement source
14 · Supporting Tables · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
controlled sample histological average score0SI Table
Exact Reported
14 · Table S4
tested implant histological average score1.67SI Table
Exact Reported
14 · Table S4
biocompatibility classificationno inflammatory reactionText
Qualitative
478 · Figure S11; Table S4

constant 1 V current readout under dynamic pressure

MOF-MSMC-5h composite film/sensor · Thin Film

response/recovery, detection limit, hysteresis, frequency, cycling and strain suppression

Geometry
1 V bias
Context
target sensor
Measurement source
477 · Pressure-Sensing Properties · Figure 2; Figures S8-S10
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
MOF-MSMC-5h stable pressure cycling10 kPa for 16,000 cyclesText
Exact Reported
477 · Figure 2i
MOF-MSMC-5h pressure detection limitMarked as a best value within this paper1 PaText
Exact Reported
477 · Figure 2f
MOF-MSMC-5h frequency response test frequencies0.5, 1, 2, and 5 HzText
Range
477 · Figure 2g
MOF-MSMC-5h pressure hysteresis under first 300 kPa press-release cycle1.8%Text
Exact Reported
477 · Figure S10
MOF-MSMC-5h pressure signal suppression of tensile strainstretch stimulus hardly changes resistanceQualitative
Qualitative
477 · Figure S8
MOF-MSMC-5h pressure recovery time at sudden ca. 5 PaMarked as a best value within this paper20 msText
Exact Reported
477 · Figure 2e
MOF-MSMC-5h pressure response/recovery at 10 kPa40 msText
Exact Reported
477 · Figure S9b
MOF-MSMC-5h pressure response/recovery at 50 kPa40 msText
Exact Reported
477 · Figure S9c
MOF-MSMC-5h pressure response/recovery at 5 kPa20 msText
Exact Reported
477 · Figure S9a
MOF-MSMC-5h pressure response time at sudden ca. 5 PaMarked as a best value within this paper20 msText
Exact Reported
477 · Figure 2e

constant 1 V current readout during pressure stimulus

MOF-PP-5h composite film/sensor · Thin Film

pressure-sensing range and GF of MOF-PP-5h control

Geometry
1 V bias
Context
PP substrate control
Measurement source
477 · Pressure-Sensing Properties · Figure S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
MOF-PP-5h pressure sensitivity segment 10.40 kPa^-1 within 30.59 kPaText
Exact Reported
477 · Figure S6
MOF-PP-5h pressure sensitivity segment 20.06 kPa^-1 under 30.59-106.08 kPaText
Exact Reported
477 · Figure S6
MOF-PP-5h pressure sensitivity segment 30.01 kPa^-1 within 106.08-250 kPaText
Exact Reported
477 · Figure S6
MOF-PP-5h pressure sensing rangeup to 250 kPaText
Rounded Reported
477 · Figure S6

constant 1 V current readout during pressure stimulus

MOF-MSMC-5h composite film/sensor · Thin Film

pressure-sensing ranges and sensitivities (GF) for MOF-MSMC sensors

Geometry
1 V bias
Context
growth-time comparison
Measurement source
12 · Supporting Tables · Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
MOF-MSMC-2.5h pressure sensitivity segment 10.81 kPa^-1 over 0-76.20 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-2.5h pressure sensitivity segment 20.21 kPa^-1 over 76.20-141.84 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-2.5h pressure sensitivity segment 30.09 kPa^-1 over 141.84-221.94 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-2.5h pressure sensitivity segment 40.03 kPa^-1 over 221.94-300 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-5h pressure sensitivity segment 1Marked as a best value within this paper61.61 kPa^-1 over 0-32.02 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-5h pressure sensitivity segment 210.94 kPa^-1 over 32.02-70.12 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-5h pressure sensitivity segment 34.02 kPa^-1 over 70.12-133.33 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-5h pressure sensitivity segment 41.08 kPa^-1 over 133.33-202.10 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-5h pressure sensitivity segment 50.36 kPa^-1 over 202.10-300 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-7.5h pressure sensitivity segment 154.54 kPa^-1 over 0-13.28 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-7.5h pressure sensitivity segment 225.0 kPa^-1 over 13.28-61.07 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-7.5h pressure sensitivity segment 32.68 kPa^-1 over 61.07-148.13 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-7.5h pressure sensitivity segment 40.83 kPa^-1 over 148.13-271.28 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-7.5h pressure sensitivity segment 50.5 kPa^-1 over 271.28-300 kPaSI Table
Exact Reported
12 · Table S2
MOF-MSMC-2.5h pressure sensing total range0-300 kPaSI Table
Range
12 · Table S2
MOF-MSMC-5h pressure sensing total rangeMarked as a best value within this paper0-300 kPaSI Table
Range
12 · Table S2
MOF-MSMC-7.5h pressure sensing total range0-300 kPaSI Table
Range
12 · Table S2

in vivo rat temporomandibular pressure monitoring

MOF-MSMC-5h sensor sealed by PDMS implant · Electrode

current variation during passive mouth opening in PO versus sham rat

Context
implant demonstration
Measurement source
477 · Pressure-Sensing Properties · Figure 2l,m
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ADD rat PO mouth-opening responsecurrent variation increases when rat widely opens mouthQualitative
Qualitative
477 · Figure 2m
Sham rat mouth-opening responsenearly no current changeQualitative
Qualitative
477 · Figure 2m