Thermoelectric — Mutually Noninterfering Flexible Pressure-Temperature Dual-Modal Sensors Based on Conductive Metal-Organic Framework for Electronic Skin

Measurement evidence

Thermoelectric

Mutually Noninterfering Flexible Pressure-Temperature Dual-Modal Sensors Based on Conductive Metal-Organic Framework for Electronic Skin · Li Y., Wang R., Wang G.-E. et al. · ACS Nano · 2022 · 473-484

2 measurement groups · 11 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

coupled pressure and temperature-gradient test

MOF-MSMC-5h composite film/sensor · Thin Film

thermal voltage under constant temperature gradient while pressure increases; pressure sensing under different temperature gradients

Context
target sensor
Measurement source
478 · Temperature-Sensing Properties · Figure 3e-f
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
pressure-sensing independence from temperature gradientspressure-sensing curves under 0, 15, and 30 K nearly overlappedQualitative
Qualitative
478 · Figure 3e
thermal voltage independence from pressurethermal voltage remains constant under 5 K and 15 K gradients while pressure increasesQualitative
Qualitative
478 · Figure 3f

Peltier TE modules with Keithley 2400 thermal voltage/current readout

MOF-MSMC-5h composite film/sensor · Thin Film

thermoelectric temperature sensing across sensor; unheated side at 25 C

Context
target sensor
Measurement source
478 · Temperature-Sensing Properties · Figure 3; Table S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
MOF-MSMC-5h temperature cycling durability100 cycles at Delta T = 20 KSI Table
Exact Reported
15 · Table S5; Figure 3d
MOF-MSMC-5h temperature cycling linearityR2 = 0.98-0.99Text
Range
478 · Figure 3d
MOF-MSMC-5h temperature recovery time7 sText
Exact Reported
478 · Figure S12
MOF-MSMC-5h temperature resolution0.1 KText
Exact Reported
478 · Figure 3b; Table S5
MOF-MSMC-5h temperature response time3 sText
Exact Reported
478 · Figure S12; Table S5
MOF-MSMC-5h absolute body-monitoring temperature span25-65 CText
Range
478 · Figure 3a
MOF-MSMC-5h temperature-gradient sensing rangeDelta T 0-40 KSI Table
Range
15 · Table S5
MOF-MSMC-5h temperature sensitivity STMarked as a best value within this paper57.1 uV/KText
Exact Reported
478 · Figure 3a; Table S5
MOF-MSMC-5h thermocurrent strain suppressionnot influenced by tensile strainQualitative
Qualitative
478 · Figure S13