Electrical Transport — Metal–Organic Frameworks Coordination-Oriented Polymer Dielectrics for Neuromorphic Vision Sensors

Measurement evidence

Electrical Transport

Metal–Organic Frameworks Coordination-Oriented Polymer Dielectrics for Neuromorphic Vision Sensors · Zhu D., Du J., Peng Z. et al. · SmartMat · 2025 · e1322

1 measurement group · 15 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

OFET transfer/output and capacitance measurements; mobility extracted from saturation-region equation

PM1-based NeuVS OFET · Electrode

Phototransistors characterized in air using Keithley 2636B; Table 1 reports Vth, Ion/Ioff, S, Ci, and mobility for PAA, PM1, PM2.

Atmosphere
air
Geometry
bottom-gate top-contact OFET array with ITO gate, PAA/PM1/PM2 dielectric, C10-DNTT semiconductor, Au source/drain
Context
PAA pristine dielectric control compared with PM1 and PM2 composites
Measurement source
5 · 3.2 · Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PAA dielectric capacitance65.99 +/- 9.93+/- 9.93Table
Exact Reported
5 · 3.2 · Table 1
PAA device Ion/Ioff5.87 +/- 0.6 x 10^5587000 dimensionless+/- 0.6 x 10^5Table
Exact Reported
5 · 3.2 · Table 1
PAA device mobility11.82 +/- 0.68+/- 0.68Table
Exact Reported
5 · 3.2 · Table 1
PAA device subthreshold swing-0.125 +/- 0.007+/- 0.007Table
Exact Reported
5 · 3.2 · Table 1
PAA device threshold voltage-0.145 +/- 0.007+/- 0.007Table
Exact Reported
5 · 3.2 · Table 1
PM1 dielectric capacitance82.71 +/- 11.63+/- 11.63Table
Exact Reported
5 · 3.2 · Table 1
PM1 device Ion/IoffMarked as a best value within this paper15.75 +/- 0.07 x 10^51575000 dimensionless+/- 0.07 x 10^5Table
Exact Reported
5 · 3.2 · Table 1
PM1 device mobilityMarked as a best value within this paper20.62 +/- 0.8+/- 0.8Table
Exact Reported
5 · 3.2 · Table 1
PM1 device subthreshold swing-0.128 +/- 0.004+/- 0.004Table
Exact Reported
5 · 3.2 · Table 1
PM1 device threshold voltage-0.285 +/- 0.007+/- 0.007Table
Exact Reported
5 · 3.2 · Table 1
PM2 dielectric capacitanceMarked as a best value within this paper95.48 +/- 4.85+/- 4.85Table
Exact Reported
5 · 3.2 · Table 1
PM2 device Ion/Ioff3.82 +/- 0.3 x 10^5382000 dimensionless+/- 0.3 x 10^5Table
Exact Reported
5 · 3.2 · Table 1
PM2 device mobility16.66 +/- 0.84+/- 0.84Table
Exact Reported
5 · 3.2 · Table 1
PM2 device subthreshold swing-0.135 +/- 0.007+/- 0.007Table
Exact Reported
5 · 3.2 · Table 1
PM2 device threshold voltage-0.15 +/- 0.014+/- 0.014Table
Exact Reported
5 · 3.2 · Table 1