Sensing Application — A Dual-Ligand Porous Coordination Polymer Chemiresistor with Modulated Conductivity and Porosity

Measurement evidence

Sensing Application

A Dual-Ligand Porous Coordination Polymer Chemiresistor with Modulated Conductivity and Porosity · Yao M.-S., Zheng J.-J., Wu A.-Q. et al. · Angewandte Chemie - International Edition · 2020 · 172-176

1 measurement group · 8 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Room-temperature chemiresistive gas sensing in a home-made dynamic sensing setup

Cu3(HHTP)(THQ) nanowire thick-film gas sensor · Thin Film

Target gas generated by certified mixtures or bubbling/drying; dry air carrier; constant flow 100 mL min-1; 5 V bias; current recorded with Keithley 2602B.

Temperature
room temperature
Atmosphere
Dry air with NH3, ethanol or acetone challenge gases
Geometry
Nanowire thick film on glass/Au interdigital electrodes
Context
pristine dual-ligand MOF thick-film device
Measurement source
2-3 · Gas sensor characterizations · Figure 4; Figures S14-S17
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NH3 limit of detection from linear plot at 3RMSapproximately 0.35 ppm3 RMSText
Approximate
175 · Results and discussion · Figure 4b; Table S4
NH3 theoretical limit of detection from log-log plotMarked as a best value within this paperapproximately 0.02 ppmText
Approximate
175 · Results and discussion · Figure 4b; Table S4
Recovery time from 10 ppm NH3Marked as a best value within this paper2.57 minText
Exact Reported
174 · Results and discussion · Figure 4a; Figure S14
Response time to 10 ppm NH3Marked as a best value within this paper1.65 minText
Exact Reported
174 · Results and discussion · Figure 4a; Figure S14
Recovery after saturated NH3 exposure~88% recovery after 80 minafter 80 minText
Approximate
13 · Figure S15 caption · Figure S15
Response time to saturated NH32.50 minText
Exact Reported
13 · Figure S15 caption · Figure S15
Selectivity toward NH3 over ethanol and acetoneGood selectivity toward NH3; ethanol and acetone responses lower in Figure 4b at high concentrationsQualitative
Qualitative
175 · Results and discussion · Figure 4b; Figures S16-S17
NH3 low-concentration detection range1-100 ppmText
Range
174 · Results and discussion · Figure 4a,b