Contact-angle/wetting observation of MOF liquid on cathode electrodes
Glass@NCM-811, 2 wt% MOF Glass coating · Powder
MOF liquid at 175-195 deg C contacted NCM-811; 175 deg C also tested on LRMO and LCO.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| MOF liquid wetting time on LRMO/LCO at 175 deg C | 6-8 s | — | — | Text Range | SI p.25 · Supplementary Fig. 23 · Supplementary Fig. 23 |
| MOF liquid wetting time on NCM-811 at 175 deg C | about 6 s from Supplementary Fig. 24 frames | — | — | Visual Estimate Approximate | SI p.26 · Supplementary Fig. 24 · Supplementary Fig. 24 |