Microscopy Morphology — Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application

Measurement evidence

Microscopy Morphology

Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application · Zhang J.-L., Gao S., Yang Y. et al. · Biosensors and Bioelectronics · 2023 · 115157

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

SEM

Ru@Ni3(HITP)2 powder · Powder

SEM images of Ni3(HITP)2 and Ru@Ni3(HITP)2 powders.

Context
Composite compared with pristine host.
Measurement source
p003-p004 · 3.1 · Fig. 1B-C; Fig. S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Stacking nanoparticle size lower bound100-200 nmText
Range
p004 · 3.1 · Fig. 1B-C; Fig. S3
Stacking nanoparticle size upper bound100-200 nmText
Range
p004 · 3.1 · Fig. 1B-C; Fig. S3