Porosity — Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application

Measurement evidence

Porosity

Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application · Zhang J.-L., Gao S., Yang Y. et al. · Biosensors and Bioelectronics · 2023 · 115157

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Literature channel and guest-size comparison cited in introduction

Ni3(HITP)2 black powder · Powder

Ni3(HITP)2 channel diameter and Ru(bpydc)3 guest size used to justify pore grafting feasibility.

Context
Pristine Ni3(HITP)2 pore-size context for Ru@Ni3(HITP)2 synthesis.
Measurement source
p002 · Introduction · Fig. S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni3(HITP)2 channel diameter~1.66 nmText
Approximate
p002 · Introduction
Ru(bpydc)3 luminophore size~1.40 nmText
Approximate