Sensing Application — Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application

Measurement evidence

Sensing Application

Ruthenium(II) complex-grafted conductive metal-organic frameworks with conductivity- and confinement-enhanced electrochemiluminescence for ultrasensitive biosensing application · Zhang J.-L., Gao S., Yang Y. et al. · Biosensors and Bioelectronics · 2023 · 115157

5 measurement groups · 20 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

ECL response control with and without AuNP decoration

Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE biosensor · Electrode

Compared Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE with Fc-S1/HT/aptamer/Ru@Ni3(HITP)2/GCE to test whether pi-pi interactions alone immobilise the aptamer/Fc-S1 quenching system.

Geometry
Modified GCE electrode
Context
Final biosensor architecture versus no-AuNP control.
Measurement source
SI text · S-17 · Fig. S12
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ECL signal with AuNP-mediated aptamer/Fc-S1 quenching1071 a.u.Text
Exact Reported
SI text · S-17 · Fig. S12
ECL signal without AuNP anchoring14138 a.u.Text
Exact Reported
SI text · S-17 · Fig. S12

Optimisation of ECL biosensor conditions

Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE biosensor · Electrode

Optimised Ru@Ni3(HITP)2 concentration, Fc-S1 concentration, and target TB/Exo I incubation time.

Geometry
Final biosensor GCE electrode
Context
Final biosensor application testing.
Measurement source
SI text · S-16 · Fig. S11
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Optimal Fc-S1 concentration2 uMText
Exact Reported
SI text · S-16 · Fig. S11B
Optimal target TB/Exo I incubation time150 minText
Exact Reported
SI text · S-16 · Fig. S11C
Optimal Ru@Ni3(HITP)2 dispersion concentration1 mg/mLText
Exact Reported
SI text · S-16 · Fig. S11A

Selectivity, reproducibility and cyclic stability ECL tests

Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE biosensor · Electrode

Selectivity versus 100 fM MUC1, beta2-MG, AFP, cholesterol and UA; reproducibility from five parallel 1 pM TB tests; stability under 20 continuous cycles at 100 pM and 1 fM TB.

Geometry
Final biosensor GCE electrode
Context
Final biosensor application testing.
Measurement source
p006 · 3.6 · Fig. 5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Reproducibility RSD for 1 pM TB0.93%five parallel testsText
Exact Reported
p006 · 3.6 · Fig. 5B
Stability RSD at 100 pM TB over 20 cyclesMarked as a best value within this paper0.47%20 cyclesText
Exact Reported
p006 · 3.6 · Fig. 5C
Stability RSD at 1 fM TB over 20 cycles1.77%20 cyclesText
Exact Reported
p006 · 3.6 · Fig. 5D

ECL thrombin calibration

Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE biosensor · Electrode

Constructed biosensor incubated with target TB concentrations under optimised conditions; ECL detected in 2 mL PBS (0.1 M, pH 7.0) containing 5 uL TPrA, 0.2-1.25 V, 0.3 V/s.

Geometry
Final biosensor GCE electrode
Context
Final Ru@Ni3(HITP)2/AuNP/aptamer/Fc-S1 biosensor.
Measurement source
SI text · S-3.5; S-19 · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Calibration interceptI = 8833.3 + 2495.1 lg[c/(pM)]Text
Exact Reported
p005 · 3.5 · Fig. 4B
Calibration slope2495.1Text
Exact Reported
p005 · 3.5 · Fig. 4B
Calibration correlation coefficientMarked as a best value within this paperR = 0.9996Text
Exact Reported
p005 · 3.5 · Fig. 4B
Thrombin linear range upper boundMarked as a best value within this paper1 fM to 1 nMText
Exact Reported
p005 · 3.5 · Fig. 4A
Thrombin linear range lower boundMarked as a best value within this paper1 fM to 1 nMText
Exact Reported
p005 · 3.5 · Fig. 4A
Thrombin detection limitMarked as a best value within this paper0.62 fM (S/N = 3)Text
Exact Reported
p005 · 3.5 · Fig. 4B
Blank ECL intensity for LOD calculationIB = 820 a.u.SB = 3.33Text
Exact Reported
SI text · S-19
LOD threshold signal ILIL = 829.99Calculated From Reported
Exact Reported
SI text · S-19

Human serum spike recovery assay

Fc-S1/HT/aptamer/AuNPs/Ru@Ni3(HITP)2/GCE biosensor · Electrode

Recovery assays measuring TB in human serum samples with five detection times per sample.

Geometry
Final biosensor GCE electrode
Context
Final biosensor application testing.
Measurement source
p006 · 3.7 · Table 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Human serum recovery at 0.01 pM added TBFound 0.00997 pM; recovery 99.7%; RSD 2.50%RSD 2.50%; n=5 detection timesTable
Exact Reported
p006 · 3.7 · Table 2
Human serum recovery at 1 pM added TBFound 1.030 pM; recovery 103.0%; RSD 2.64%RSD 2.64%; n=5 detection timesTable
Exact Reported
p006 · 3.7 · Table 2
Human serum recovery at 100 pM added TBFound 104.1 pM; recovery 104.1%; RSD 4.86%RSD 4.86%; n=5 detection timesTable
Exact Reported
p006 · 3.7 · Table 2
Human serum recovery at 1000 pM added TBFound 1028 pM; recovery 102.8%; RSD 3.23%RSD 3.23%; n=5 detection timesTable
Exact Reported
p006 · 3.7 · Table 2