Other — A conductive metal-organic framework-modified electrode for sensitive electrochemiluminescent detection of cardiac Troponin I

Measurement evidence

Other

A conductive metal-organic framework-modified electrode for sensitive electrochemiluminescent detection of cardiac Troponin I · Murray A., Valenti G., Baker P. · Electrochimica Acta · 2026 · 148350

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Thermogravimetric analysis using TGA 4000

Cu3(HHTP)2 blue-black powder · Powder

Mass changes of Cu3(HHTP)2 on heating.

Context
pristine c-MOF powder
Measurement source
p004 · 3.1 Characterization · Figure 1D
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
First TGA mass loss8.03 % between 100 deg C and approximately 250 deg CText
Exact Reported
p004 · 3.1 Characterization · Figure 1D
Second TGA mass loss69.05 % between 250 deg C and 350 deg CText
Exact Reported
p004 · 3.1 Characterization · Figure 1D