Spectroscopy — A conductive metal-organic framework-modified electrode for sensitive electrochemiluminescent detection of cardiac Troponin I

Measurement evidence

Spectroscopy

A conductive metal-organic framework-modified electrode for sensitive electrochemiluminescent detection of cardiac Troponin I · Murray A., Valenti G., Baker P. · Electrochimica Acta · 2026 · 148350

4 measurement groups · 15 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

EDX coupled to SEM

SPCE/Cu3(HHTP)2 · Electrode

Elemental composition of Cu3(HHTP)2 compared with theoretical values.

Geometry
drop-coated electrode surface
Context
c-MOF/SPCE composite electrode
Measurement source
p002 · Table S1 · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
EDX composition agreementelemental composition closely aligned with theoretical values for Cu3(HHTP)2Text
Qualitative
p004 · 3.2 Morphological characterization · Table S1
Experimental C atomic fraction68.70 +/- 0.87 at%+/- 0.87 at%SI Table
Exact Reported
p002 · Table S1 · Table S1
Theoretical C atomic fraction70.59 at%SI Table
Exact Reported
p002 · Table S1 · Table S1
Experimental Cu atomic fraction6.79 +/- 1.66 at%+/- 1.66 at%SI Table
Exact Reported
p002 · Table S1 · Table S1
Theoretical Cu atomic fraction5.88 at%SI Table
Exact Reported
p002 · Table S1 · Table S1
Experimental O atomic fraction24.51 +/- 1.27 at%+/- 1.27 at%SI Table
Exact Reported
p002 · Table S1 · Table S1
Theoretical O atomic fraction23.53 at%SI Table
Exact Reported
p002 · Table S1 · Table S1

FTIR spectroscopy using PerkinElmer Spectrum 100

Cu3(HHTP)2 blue-black powder · Powder

Vibrational assignments for Cu3(HHTP)2.

Context
pristine c-MOF powder
Measurement source
p004 · 3.1 Characterization · Figure 1B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FTIR C-O stretching band1307 cm^-1Text
Exact Reported
p004 · 3.1 Characterization · Figure 1B
FTIR C=O stretching band1628 cm^-1Text
Exact Reported
p004 · 3.1 Characterization · Figure 1B
FTIR O-H/C-H broad band3500-3300 cm^-1 broad bandrangeText
Range
p004 · 3.1 Characterization · Figure 1B

Raman spectroscopy using i-Raman Plus 785H portable spectrometer, 785 nm excitation

Cu3(HHTP)2 film on aluminium foil · Thin Film

Cu3(HHTP)2 and HHTP drop-cast on aluminium foil and dried overnight.

Geometry
thin film on aluminium foil
Context
pristine c-MOF film and HHTP comparison
Measurement source
p004 · 3.1 Characterization · Figure 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Raman aromatic C-C stretching bands1367, 1458, and 1540 cm^-1Text
Exact Reported
p004 · 3.1 Characterization · Figure 2
Raman metal ion vibrationabout 190 cm^-1~Text
Approximate
p004 · 3.1 Characterization · Figure 2

UV-Vis absorption spectroscopy using GENESYS 50 UV-Vis spectrophotometer

Cu3(HHTP)2 blue-black powder · Powder

Absorption spectrum of Cu3(HHTP)2.

Context
pristine c-MOF powder
Measurement source
p004 · 3.1 Characterization · Figure 1C
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
UV-Vis LMCT band range550-800 nm broad absorption bandrangeText
Range
p004 · 3.1 Characterization · Figure 1C
UV-Vis n-pi transition band268 nmText
Exact Reported
p004 · 3.1 Characterization · Figure 1C
UV-Vis pi-pi transition band364 nmText
Exact Reported
p004 · 3.1 Characterization · Figure 1C