Thermopower under temperature gradient
General Cu-BHT thin-film samples · Thin Film
Two 30 nm gold electrodes separated by 5 mm on Cu-BHT film transferred to SiO2; Peltier cooler/heater applied temperature gradient; temperature difference by FLIR A300 thermal camera and thermoelectric potential by Keithley 4200 SCS.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Thermopower range | -4 to -10 uV K-1 | — | — | Text Range | main p.5 · Electrical conductivity |