Spectroscopy — Ultrafast in Situ Synthesis of Large-Area Conductive Metal-Organic Frameworks on Substrates for Flexible Chemiresistive Sensing

Measurement evidence

Spectroscopy

Ultrafast in Situ Synthesis of Large-Area Conductive Metal-Organic Frameworks on Substrates for Flexible Chemiresistive Sensing · Chen X., Lu Y., Dong J. et al. · ACS Applied Materials and Interfaces · 2020 · 57235-57244

5 measurement groups · 53 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

In situ FTIR during NH3 sensing

Cu-BHT-2 min chemiresistor sensor on Si/SiO2/Au interdigitated electrodes · Electrode

20 ppm NH3 introduced at 5 mL/min after N2 purge; spectra every 30 s

Atmosphere
N2/NH3
Geometry
Cu-BHT-2min film in testing cabin
Context
pristine Cu-BHT active film
Measurement source
p007-p008; article pages 57241-57242 · 3.5 Sensing Mechanism · Figure 5b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FTIR band assigned to NH3-Cu2c1214 cm-1; NH3 coordinated to Lewis acid sitesText
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5b
FTIR band assigned to NH3-Cu2c1370 cm-1; coordinatively adsorbed NH3 on Lewis acid sitesText
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5b
FTIR band assigned to gas-phase NH31737 cm-1; free gas-phase NH3Text
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5b
FTIR band assigned to NH4+3021 cm-1; small amount of NH4+Text
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5b

UPS before/after NH3 sensing

Cu-BHT-2 min chemiresistor sensor on Si/SiO2/Au interdigitated electrodes · Electrode

Cu-BHT-2min film before and after NH3 exposure

Atmosphere
ambient
Geometry
thin-film sensor
Context
pristine Cu-BHT active film
Measurement source
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Fermi level increase after NH3 sensing0.54 eVText
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5c
HOMO energy increase after NH3 sensing0.72 eVText
Exact Reported
p008; article page 57242 · 3.5 Sensing Mechanism · Figure 5c

XPS Cu 2p deconvolution

Cu-BHT film reaction-time series · Thin Film

Cu4c and Cu2c surface percentages versus reaction time

Atmosphere
ambient
Geometry
thin films
Context
pristine Cu-BHT films
Measurement source
p014 · Table S3 · Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu2c percentage Cu-BHT-10min40.12%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-12min36.47%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-14min32.23%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-2min52.49%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-4min50.23%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-5sMarked as a best value within this paper56.38%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-6min48.32%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu2c percentage Cu-BHT-8min45.07%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-10min59.88%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-12min63.53%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-14min67.77%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-2min47.51%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-4min49.77%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-5s43.62%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-6min51.68%SI Table
Exact Reported
p014 · Table S3 · Table S3
Cu4c percentage Cu-BHT-8min54.93%SI Table
Exact Reported
p014 · Table S3 · Table S3

XPS before/after NH3 sensing

Cu-BHT-2 min chemiresistor sensor on Si/SiO2/Au interdigitated electrodes · Electrode

Survey and N 1s spectra; elemental percentages before and after NH3 sensing

Atmosphere
ambient
Geometry
Cu-BHT-2min film
Context
pristine Cu-BHT active film
Measurement source
p014 · Figure S13 and Table S4 · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu after NH3 sensing9.44%SI Table
Exact Reported
p014 · Table S4 · Table S4
N after NH3 sensing11.43%SI Table
Exact Reported
p014 · Table S4 · Table S4
S after NH3 sensing20.28%SI Table
Exact Reported
p014 · Table S4 · Table S4
Cu before NH3 sensing12.75%SI Table
Exact Reported
p014 · Table S4 · Table S4
N before NH3 sensing1.99%SI Table
Exact Reported
p014 · Table S4 · Table S4
S before NH3 sensing26.02%SI Table
Exact Reported
p014 · Table S4 · Table S4
N content increase after NH3 sensingnearly a factor of 6Text
Approximate
p008; article page 57242 · 3.5 Sensing Mechanism · Figure S13/Table S4

XPS elemental composition

Cu-BHT film reaction-time series · Thin Film

Surface S, Cu and S/Cu ratios versus reaction time

Atmosphere
ambient
Geometry
thin films
Context
pristine Cu-BHT films
Measurement source
p011 · Table S2 · Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu percentage Cu-BHT-10min10.45%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-12min11.28%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-14min12.75%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-2min9.89%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-4min10.4%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-5s6.66%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-6min10.67%SI Table
Exact Reported
p011 · Table S2 · Table S2
Cu percentage Cu-BHT-8min10.71%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-10min26.03%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-12min26.14%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-14min26.92%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-2min26.07%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-4min26.55%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-5s25.4%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-6min26.43%SI Table
Exact Reported
p011 · Table S2 · Table S2
S percentage Cu-BHT-8min26.49%SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-10min2.49SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-12min2.31SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-14min2.11SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-2min2.63SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-4min2.55SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-5s3.81SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-6min2.48SI Table
Exact Reported
p011 · Table S2 · Table S2
S/Cu ratio Cu-BHT-8min2.47SI Table
Exact Reported
p011 · Table S2 · Table S2