Sensing Application — Conductive Hybrid Cu-HHTP-TCNQ Metal–Organic Frameworks for Chemiresistive Sensing

Measurement evidence

Sensing Application

Conductive Hybrid Cu-HHTP-TCNQ Metal–Organic Frameworks for Chemiresistive Sensing · Luder L., Gubicza A., Stiefel M. et al. · Advanced Electronic Materials · 2022 · 2100871

1 measurement group · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Pressure-dependent chemiresistive resistance response during gas venting/pumping

Cu-HHTP-TCNQ film on glass chip with prepatterned gold electrodes, 45 min · Electrode

Vacuum chamber flushed with nitrogen, dry air, and ambient air at 41% relative humidity while monitoring film resistance and pressure; average of N = 3.

Temperature
room temperature
Atmosphere
Nitrogen, dry air, ambient air (41% RH), vacuum
Geometry
Same 45 min device as representative I-V; contact spacing s = 20 um
Context
Hybrid film proof-of-principle chemiresistive sensing
Measurement source
11 · Figure S9 · Figure S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Normalised conductivity in ambient air relative to nitrogenln(sigma/sigma_N2) about -1.0 for ambient air from Figure 4hvisual error bar roughly +/-0.3Figure Axis
Approximate
6 · Figure 4 caption · Figure 4h
Normalised conductivity in dry air relative to nitrogenln(sigma/sigma_N2) about +0.6 for dry air from Figure 4hvisual error bar roughly +/-0.2Figure Axis
Approximate
6 · Figure 4 caption · Figure 4h
SI gas trace sample and spacingCu-HHTP-TCNQ film synthesised at 0 C for 45 min; contact spacing s = 20 umCaption
Exact Reported
11 · Figure S9 caption · Figure S9
Approximate saturated relative resistance response in ambient airMarked as a best value within this paperDeltaR/R about 0.95 at atmospheric pressure from Figure 4gFigure Axis
Approximate
6 · Figure 4 caption / 2.7. Chemiresistive Response · Figure 4g
Approximate saturated relative resistance response in dry airDeltaR/R about 0.70 at atmospheric pressure from Figure 4gFigure Axis
Approximate
6 · Figure 4 caption / 2.7. Chemiresistive Response · Figure 4g
Approximate saturated relative resistance response in nitrogenDeltaR/R about 0.85 at atmospheric pressure from Figure 4gFigure Axis
Approximate
6 · Figure 4 caption / 2.7. Chemiresistive Response · Figure 4g
Pressure where resistance starts to riseabout 10^-1 mbarText
Approximate
7 · 2.7. Chemiresistive Response · Figure 4g
Ambient-air relative humidity during sensing test41% relative humidityText
Exact Reported
7 · 2.7. Chemiresistive Response · Figure 4g
Number of gas-response repeatsaverage of N = 3Caption
Exact Reported
6 · Figure 4 caption · Figure 4g